CERTIFIED LIFE-SAFETY ENGINEERING

Fire-Rated Protection Engineered to TS EN 1634-1.

Professional fire-rated door systems featuring 60, 90, and 120-minute resistance options, intumescent smoke seals, and concealed or surface-mounted panic exit bars.

  • 60, 90 and 120-minute fire resistance options
  • Heat-expanding intumescent smoke-sealing gaskets
  • Concealed and surface-mounted panic bar compatibility
  • Single-leaf and double-leaf production in any RAL color
ERLİN KAPI red certified fire door with panic exit bar

MODELS & SERIES

Fire Doors Catalog Models

Escape StairwellsHotels & HospitalsSchools & Public BuildingsParking & Technical Rooms
Technical & Installation NoteConfigured to TS EN 1634-1 standards in 60, 90, and 120-minute fire resistance options with intumescent smoke seals, panic exit bars, and hydraulic door closers.
TECHNICAL PLANNING GUIDE · FIRE SAFETY

Fire Door Specification & Planning Criteria

General planning guidance only; exact fire resistance classification, certification scope, and hardware are verified per project quotation.

01

Resistance Duration by Building Use

Select 60, 90, or 120-minute configurations according to the building's fire strategy and escape route requirements.

02

Panic Bar & Escape Direction

Opening direction toward egress, single-motion panic bars, and hydraulic closers ensure reliable emergency exit.

03

Intumescent Smoke Seals

Heat-expanding perimeter seals swell under high temperatures to help restrict smoke passage around the leaf.

04

Site Opening & Frame Installation

Stairwell masonry openings should be finalized with finished floor levels in mind before frame anchoring.

On-Site Laser Survey (Bursa) & Project Shipping

Dedicated Installation Teams in Yıldırım, Nilüfer, Osmangazi, Gürsu & Kestel

Showroom Address: Arabayatağı, Ankara Yolu Cd. No:325/7, 16290 Yıldırım/Bursa · Project Director: 0543 331 36 16

Project Director: 0543 331 36 16

FREQUENTLY ASKED QUESTIONS

Fire Doors — Frequently Asked Questions

What fire resistance options are available?

Depending on project specifications, we manufacture TS EN 1634-1 fire-rated doors in 60, 90, and 120-minute configurations.

Are panic bars and hydraulic closers included?

Yes. Concealed or surface panic exit bars, push hardware, and door closers are configured according to your project spec.

Can fire doors be powder-coated in custom RAL colors?

Yes. Beyond standard fire red, doors can be finished in any custom RAL powder-coat color.

Do you manufacture double-leaf fire doors?

Yes. Both single-leaf and double-leaf fire doors are produced to match site structural openings.

QUICK QUOTATION

Fire Doors — Request a Custom Project Quote

01 — Client & Project Profile

02 — Door System & Dimensions

03 — Contact Information